inquiry
Leave Your Message
slide1
01
Products Categories

SMD Termination CVD

Key Features
● Nominal Impedance: 50 Ω
● Resistance Tolerance: ±5% (default)
● Substrate Material: CVD
● Power Rating: 20W-300W
● Frequency Range: DC-42.5GHz
● Temperature Coefficient: ±300ppm/℃
● Operating Temperature: -55℃ to +150℃
● Installation Method: Gold wire bonding on the front side, soldering or bonding on the back.

SMD Termination CVDpdf.png

    Part Number Substrate Power Rating (W) Frequency Range (GHz) VSWR (Max.) Dimensions (mm)
    L W T
    ST50C-20-801A CVD 20 DC-42.5 1.40 :1 0.98 0.98 0.32
    ST50C-25-201A CVD 25 DC-7 1.20 :1 1.6 0.89 0.38
    ST50C-25-601A CVD 25 DC-26 1.60 :1 1.7 0.9 0.38
    ST50C-50-302A CVD 50 DC-20 1.60 :1 1.4 1.4 0.38
    ST50C-100-002A CVD 100 DC-18 1.50 :1 2.16 1.4 0.38
    ST50C-150-202A CVD 150 DC-14 1.40 :1 3.4 2.7 0.38
    ST50C-300-201A CVD 300 DC-6 1.25 :1 4.06 3.05 0.38

    * Customized products are available, please consult with Kete.

    Installation Instruction:
    1.The front side is connected by gold wire bonding.The bottom side is welding or bonding.
    2. The back side is bonded with conductive adhesive or welded with solder paste below 320 degrees.

     

    Usage Precautions

    1. Storage Conditions: It is recommended to store in a constant temperature and humidity warehouse.
    2. When manually welding the lead end, a constant temperature soldering iron ≤350℃ should be used, and the welding time should be controlled within 5 seconds.
    3. The front electrode port should be bonded with gold wire.
    4. To meet the derating curve, install a radiator with a large enough size. Solder paste should be sintered between the metal surface and the radiator, and the solder should melt for less than 5 seconds. Add air cooling or water cooling if necessary.